Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Hiroki, Akihiro; Yamashita, Shinichi*; Taguchi, Mitsumasa
Journal of Physics; Conference Series, 573(1), p.012028_1 - 012028_4, 2015/01
Times Cited Count:4 Percentile:78.9(Engineering, Biomedical)Polymer gel dosimeters based on radiation-crosslinked hydroxypropyl cellulose gel were prepared, which comprised 2-hydroxyethyl methacrylate (HEMA) and polyethylene glycol dimethacrylate (9G) as less toxic monomers and tetrakis (hydroxymethyl) phosphoniumu chloride (THPC) as an antioxidant. The dosimeters exposed to Co -rays became cloudy at only 1 Gy. The irradiated dosimeters were optically analyzed by using a UV-vis spectrophotometer to evaluate dose response. Absorbance of the dosimeters linearly increased in the dose range from 0 to 10 Gy. The dose sensitivity increased with increasing 9G concentration. The dosimeter with 2 wt% HEMA, 3 wt% 9G, and 0.16 wt% THPC exhibited about 0.04 Abs Gy of the dose sensitivity. The dose sensitivity of the dosimeters was also enhanced by increment in THPC, reached about 0.06 Abs Gy at 0.40 wt% THPC.
Kume, Tamikazu
IAEA-SM-365/22, p.90 - 94, 2003/09
no abstracts in English
Kume, Tamikazu; Nagasawa, Naotsugu*; Yoshii, Fumio
Radiation Physics and Chemistry, 63(3-6), p.625 - 627, 2002/03
Times Cited Count:95 Percentile:97.77(Chemistry, Physical)no abstracts in English
Kume, Tamikazu
Proceedings of International Nuclear Conference 2002 (INC '02), p.128 - 135, 2002/00
no abstracts in English
Kume, Tamikazu
Hoshasen To Sangyo, (90), p.41 - 45, 2001/06
no abstracts in English
Kume, Tamikazu
Porima Daijesuto, 53(3), p.17 - 26, 2001/03
no abstracts in English
Hien, N. Q.*; Nagasawa, Naotsugu*; Tham, L. X.*; Yoshii, Fumio; Dang, V. H.*; Mitomo, Hiroshi*; Makuuchi, Keizo; Kume, Tamikazu
Radiation Physics and Chemistry, 59(1), p.97 - 101, 2000/07
Times Cited Count:105 Percentile:98.47(Chemistry, Physical)no abstracts in English
Makuuchi, Keizo
Hoshasen Riyo Ni Okeru Saikin No Shimpo, p.87 - 100, 2000/06
no abstracts in English
Functional Materials Laboratory I
JAERI-Conf 2000-003, p.174 - 0, 2000/03
no abstracts in English
Kume, Tamikazu
JAERI-Conf 2000-003, p.87 - 93, 2000/03
no abstracts in English
Makuuchi, Keizo
Porima Daijesuto, 51(10), p.81 - 100, 1999/10
no abstracts in English
Kume, Tamikazu; Nagasawa, Naotsugu*; Yoshii, Fumio; Tham, L. X.*; Hien, N. Q.*; Ha, P. T. L.*; Lam, N. D.*
Conference Proceeding RadTech Asia'99, p.475 - 480, 1999/00
no abstracts in English
Nagasawa, Naotsugu*; Mitomo, Hiroshi*; Yoshii, Fumio; Makuuchi, Keizo; Kume, Tamikazu
Shokuhin Shosha, 34(1-2), p.37 - 42, 1999/00
no abstracts in English
Kume, Tamikazu
Yuki Zairyo Eno Hoshasen Riyo No Shin Tenkai Koen Yoshishu, p.1 - 6, 1998/00
no abstracts in English
Hosoi, Fumio; *; ; *
Kobunshi Rombunshu, 42(6), p.415 - 422, 1985/00
Times Cited Count:2 Percentile:22.32(Polymer Science)no abstracts in English
JAERI-M 83-161, 96 Pages, 1983/11
no abstracts in English
Hiroki, Akihiro; Yamashita, Shinichi*; Kimura, Atsushi; Nagasawa, Naotsugu; Taguchi, Mitsumasa
no journal, ,
The polymer gel dosimeters consisting of 2-hydroxyethyl methacrylate, nonaethylene glycol dimethacrylate, and tetrakis (hydroxymethyl) phosphoniumu chloride with radiation-crosslinked hydroxypropyl cellulose gel were irradiated with 290 MeV/u C ions at HIMAC. Absorbance of the irradiated dosimeters at 660 nm increased with an increase in the dose up to 10 Gy. The dose response of the dosimeter irradiated with C ions was about 0.007 Abs. Gy, which decreased in about one-tenth of the -irradiated sample. RGB value of the image obtained by using a flat-bed image scanner also increased with increasing dose. Distribution of the dose estimated from RGB value of the scanned image was almost agreement with that of a general radiochromic film for the radiotherapy.